Date Range:
Monday, January 1, 2018 to Monday, November 5, 2018
Publication Date:
Wednesday, December 2, 2020
Dissolved oxygen and water temperature were measured using a HOBO datalogger attached to the outside of a PVC pipe in the center of the stream channel.
Dissolved oxygen percent saturation was calculated using HOBOware software and barometric pressure data from the MBL Marshview Farm Field Station, Newbury, MA.
ADDITIONAL RESEARCH LOCATION COORDINATES: In addition to the decimal degree coordinates given above, locations are also given here in Massachusetts State Plane coordinates. The stream is called Saw Mill Br. and is located in Burlington MA. Small amounts of forest remain (~14% in 1999), much of which is along the stream channel near the gaging site.
STATION STATE X STATE Y
YSI-SB 225840 919310
NOTES AND COMMENTS: HOBO dissolved oxygen loggers have a sensor cap that requires replacement every 7 months. If the logger is deployed when the sensor cap expires, no usable data is collected after that point.
FLAGS:
1 -- Datalogger not deployed
2 -- Datalogger malfunction
3 -- Datalogger was deployed but with an expired sensor cap
Measurements completed for the year.
Version 01: December 2, 2020, data and metadata updates to comply with importation to DEIMS7 and LTER Data Portal. Used MarcrosExportEML_HTML (working)pie_excel2007_Sep2020.xlsm 9/17/20 1:11 PM for QA/QC to EML 2.1.0.