rivers

PIE LTER Year 2015, 15 minute measurements of dissolved oxygen, water temperature at the Ipswich River head of tide, Sylvania Dam in Ipswich, MA.

Abstract: 

Year 2015, continuous measurements, every 15 minutes were made of dissolved oxygen, water temperature in the Ipswich River behind the head of tide Sylvania Dam in Ipswich, MA.

Core Areas: 

Data set ID: 

448

Keywords: 

Short name: 

WAT-SylvaniaDamIpswich-DO-2015

Data sources: 

WAT-SylvaniaDamIpswich-DO-2015_csv
WAT-SylvaniaDamIpswich-DO-2015_xls

Methods: 

Dissolved oxygen and water temperature were measured using a HOBO datalogger secured inside a perforated PVC pipe attached to the south dam abutment.

Dissolved oxygen percent saturation was calculated using HOBOware software and barometric pressure data from Marshview Farm.

NOTES AND COMMENTS:
HOBO dissolved oxygen loggers have a sensor cap that requires replacement every 7 months. If the logger is deployed when the sensor cap expires, no usable data is collected after that point.

FLAGS:
1 -- Datalogger not deployed
2 -- Datalogger was deployed but with an expired sensor cap

Maintenance: 

Measurements completed for year

Version 01: February 7, 2018, data and metadata created to comply with importation to Drupal and LTER PASTA. Used MarcrosExportEML_HTML (working)pie_excel2007_Jan2018.xlsm 1/30/2018 2:24 PM for QA/QC to EML 2.1.0